Compare Model Drawings, CAD & Specs Communication Interfaces Number of Ports Slits Wavelength Range Grating Type Availability Price
$7,700
1 Week
USB 2.0 and RS232 2 Fixed Slit Holders 200-1200 nm Ruled
1 Week
$8,200
2 Weeks
USB 2.0 and RS232 2 Micrometer Driven 200-1200 nm Ruled
2 Weeks
$7,300
1 Week
USB 2.0 and RS232 2 Fixed Slit Holders 200-1000 nm Holographic
1 Week
$7,800
In Stock
USB 2.0 and RS232 2 Micrometer Driven 200-1000 nm Holographic
In Stock
$7,500
6 Weeks
USB 2.0 and RS232 2 Fixed Slit Holders 300-2200 nm Ruled
6 Weeks
$8,000
1 Week
USB 2.0 and RS232 2 Micrometer Driven 300-2200 nm Ruled
1 Week
$7,000
1 Week
USB 2.0 and RS232 2 Fixed Slit Holders 600-2200 nm Ruled
1 Week
$7,500
1 Week
USB 2.0 and RS232 2 Micrometer Driven 600-2200 nm Ruled
1 Week
USB 2.0 and RS232 2 280 - 2500 nm, grating dependent

Features

Overview Video

This video presents an overview of the Cornerstone 130B 1/8m monochromator's features and its Mono-Utility user interface software capabilities. It also demonstrates a quick guide to product configuration and setup.

Fixed Slit Versions

Fixed slits should be used for the utmost accuracy and repeatability, especially at high resolution. Fixed slits are the best option when only a few slit sizes are required, as they are less expensive. The fixed slits slide into the holder at the input port, as well as the holder at the lateral output port on dual output models. The width and height cannot be adjusted, but may be individually replaced with other slit sizes. Individual fixed slits are required and sold separately to allow customized choices based on the needs of the application (see accessory section). Order two identical fixed slits for the CS130(B) monochromator. The slit width is one of the factors determining the resolution and throughput of the instrument, with a narrow slit providing higher resolution and lower throughput.

Micrometer Adjustable Slit Versions

Micrometer adjustable slits offer flexibility and high throughput, but are not as accurate or repeatable as fixed slits. The micrometer adjustable slit assembly is continuously variable from fully closed to 3 mm width. The narrowest practically achievable width is 4 µm. A height adjustment slide allows variation in the height from 2 to 12 mm. This type of slit is designed primarily for versatility and convenience in changing resolution and throughput.

Optional Hand Controller

All models include a connector to utilize the optional 74009 Hand Controller for manual operation without a computer. There is no need to memorize commands or key sequences. The display provides information on the grating selection, active filter selected, current wavelength, and shutter status and more.