Model PSCOUT2-BASE is the Base Model of the PulseScout2 Autocorrelator family that can measure 20 – 3500 fsec pulses, between 420 – 1600 nm wavelength. This device is not equiped with a detection module. A detection module is required for desired wavelength and sensitivity (i.e. PMT or PD).
The PulseScout2™ autocorrelators are a versatile, easy-to-use diagnostic tool for measuring ultrafast pulses. This autocorrelator family is capable of measuring pulse widths from both high repetition rate (MHz) oscillators and low repetition rate (kHz) amplifiers from visible to IR wavelength range. A photodiode detector module is suitable to detect and measure high-energy amplified pulses, and a photomultiplier detector module is to measure low-energy oscillator pulses. Conveniently, these detector modules are fully interchangeable in seconds. Alignment is straight-forward and can also be done easily even for first time users, making this autocorrelator an ideal diagnostic tool for all of your ultrafast applications. CE compliant, and includes a 12 VDC 90 Watt power supply.
Sensitivity is typically 0.1 W², UV range < 500 W².
Broad Ultrafast Pulse Width Capability
The PulseScout2 is a Michelson interferometer based autocorrelator capable of measuring pulse widths from 20 fs to 3.5 ps in the 420 -1600 nm wavelength range. It requires horizontally polarized input with a minimum beam diameter of 2 mm (1/e2). The base model contains the optical head shown on the left and control unit shown on the right. Interchangeable detector modules are offered but are not included with the base model.
Interchangeable Detector Modules
The PulseScout Detector modules are available in BLUE (420 - 550nm), RED (520 - 750nm), NIR (700 - 100nm), and IR (1000 - 1600nm). Two versions are offered for each wavelength range: photomultiplier tube PMT models for high repetition rate (MHz) oscillators (such as Tsunami®) and photodiode detector PD models for low repetition rate (kHz) amplifiers (such as Spitfire® Ace™). Each detector comes with a low-pass filter and SHG crystal.
Easy to Set up and Reconfigure
The PulseScout2 optical head in base model does not include a detector module. Interchangeable detector modules can be used with the same autocorrelator optical head. You can simply replace the detector module to change the wavelength range or detector type in seconds.
PSCOUT2-NIR-PMTPMT Detector Module, NIR, 700-1100 nm, Inc. SHG Crystal, PulseScout2
UNIVERSAL
In Stock
$7,900
PSCOUT2-NIR-PDPD Detector Module, NIR, 700-1100 nm, Inc. SHG Crystal, PulseScout2
UNIVERSAL
In Stock
$4,500
PSCOUT2-IR-PMTPMT Detector Module, IR, 1000-1600 nm, Inc. SHG Crystal, PulseScout2
UNIVERSAL
In Stock
$6,570
PSCOUT2-BASE - Drawings & CAD
Additional CAD file downloads are not available for this product.
PSCOUT2-BASE - Drawings
Additional drawings are not available for this product.
PSCOUT2-BASE
Sign In
Request Resource
In order to provide better service and products, please provide the following brief information.
Password Reset
Enter your email address below to reset your account password.
Password Reset
Email Verification Required
Cart Items Updated
Remove Product
Remove this product from your comparison list?
Check Order Status
Provide an order number and postal code to check the status of an order or download an invoice for an order that has shipped. Login to view your complete order history.
Sign In Required
To access this and other valuable technical resources, please sign in or register for a new online account.
Add to Cart
PulseScout2 Autocorrelator, Base Model, 20-3500 fs, 420-1600 nm