Product Description
This family of InGaAs and Ge detectors covers the spectal information rich 0.7 to 2.5 mm NIR measurements. These detectors are operated in the photovoltaic (unbiased) mode to provide the lowest noise for DC and low frequency operation since it avoids the shot noise associated with bias currents. One unit, model 71898, comes with a DC bias arrangement producing 1 ns rise times. We offer amplified and unamplified, calibrated and non calibrated models, as well as TE cooled and room temperature versions. Their large areas make signal capture easy. The 1.5 Inch Series flange allows instant connectivity to other Oriel instruments, such as monochromator exit slit assemblies. Use the Ge detectors to get beyond the 1.6 mm limit of standard InGaAs.
This family of InGaAs and Ge detectors covers the spectal information rich 0.7 to 2.5 mm NIR measurements. These detectors are operated in the photovoltaic (unbiased) mode to provide the lowest noise for DC and low frequency operation since it avoids the shot noise associated with bias currents. One unit, model 71898, comes with a DC bias arrangement producing 1 ns rise times. We offer amplified and unamplified, calibrated and non calibrated models, as well as TE cooled and room temperature versions. Their large areas make signal capture easy. The 1.5 Inch Series flange allows instant connectivity to other Oriel instruments, such as monochromator exit slit assemblies. Use the Ge detectors to get beyond the 1.6 mm limit of standard InGaAs.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ordering Information | InGaAs and Ge Detectors | | Quantity | Model | Description | Price | | | 71615 | InGaAs Detector, 3mm Dia, 100ns Rise Time | | | | 71655 | InGaAs Detector, 3mm Dia, 100ns Rise Time, Calibrated | | | | 71616 | TE Cooled InGaAs Detector, 3mm Dia, 100ns Rise Time | | | | 71656 | TE Cooled InGaAs Detector, 3mm Dia, 100ns Rise Time, Calibrated | | | | 71886 | Amplified InGaAs Detector, 3mm Diameter | | | | 71892 | Amplified InGaAs Detector, 3mm Dia, Calibrated | | | | 71887 | TE Cooled Amplified InGaAs Detector, 3mm Diameter | | | | 71893 | TE Cooled Amplified InGaAs Detector, 3mm Dia, Calibrated | | | | 71898 | Biased InGaAs Detector, 0.3mm Dia, 1ns Rise Time | | | | 71613 | Germainium Detector, 5mm Dia, 0.5ms Rise Time | | | | 71653 | Germainium Detector, 5mm Dia, 0.5ms Rise Time, Calibrated | | | | 71614 | TE Cooled Germainium Detector, 5mm Dia, 0.5ms Rise Time | | | | 71654 | TE Cooled Germainium Detector, 5mm Dia, 0.5ms Rise Time, Calibrated | | | | 71617 | Amplified Germainium Detector, 5mm Diameter | | | | 71627 | Amplified Germainium Detector, 5mm Diameter, Calibrated | | | | 71618 | TE Cooled Amplified Germainium Detector, 5mm Diameter | | | | 71628 | TE Cooled Amplified Germainium Detector, 5mm Diameter, Calibrated | |
| Accessories | | Quantity | Model | Description | Price | | | 77055 | TE Cooler Controller | | | | 70703 | Labratory Power Supply, +/- 15 VDC, 115 VAC | | | | 70709 | Labratory Power Supply, +/- 15 VDC, 230 VAC | |
|
|